Song Meter Mini and Mini Bat firmware update

A new firmware update is available for the Song Meter Mini and Song Meter Mini Bat. Version 1.4 will introduce the following changes:

  • Mini Bat now reports scheduled recording period to the app correctly.
  • Mini Bat now correctly increments the recording counter in zero-crossing only mode.
  • Improvements for battery performance.
Instructions for updating the firmware

To upgrade the Song Meter Mini or Song Meter Mini Bat firmware:

  1. Download the firmware file.
  2. Copy this file to the top-level directory of a flash memory card. There must be only one firmware file on the card.
  3. Insert the flash memory card into the SD card slot of the Song Meter Mini.
  4. Turn on the Song Meter Mini.
  5. Press the FUNCTION button two times to select the ‘LOAD’ function.
  6. Press and hold the FUNCTION button until the ‘LOAD’ LED begins blinking.
  7. When the process is complete, all four LEDs will blink green three times and the recorder will reboot with the new firmware.

Anabat Swift Firmware Update – May 2020

A new firmware update (V1.6) is available for the Anabat Swift. This update will introduce the following changes:

• Spanish language added.
• Low battery warning messages clarified
• Bug fix: “Constant Recording” didn’t always start when expected
• Bug fix: Display of months in the schedule editor
• Several usability improvements
• Improved menu layout

 

This update should be installed on all your detectors as soon as possible to ensure that they continue to run smoothly. Full instructions below.

Method 1 – Using an SD Card

Step 1 – Download the update file using this link and copy it to the root directory on your SD card. Make sure the file is named swift.adx. You can use the same SD card to update multiple Swifts.

Step 2 – Insert the SD card and fresh batteries into your Swift then power it on. Make sure that there isn’t a second SD card in the Swift. After a short time the following message will appear: “Swift update 1.6 available. Would you like to update?” Press “Yes” to start the update. Do not remove the batteries or power off the detector while the update is being installed. The red Mode lights will flash in sequence while the update is being installed. When the flashing stops, your Swift will restart with the new firmware. You may get a message about a new “bootloader available”; if so, please proceed with this update by pressing the “Upgrade” button.

If your Swift doesn’t detect the software update on the SD card, it may be using a very old firmware version. If this is the case you will need to follow Method 2 (below).

Method 2 – Using Insight and a USB cable

If you haven’t used your computer to update your Swift previously, you will need to follow Step 1 to install the necessary software on your PC. If you’ve already done this before, skip ahead to Step 2.

Step 1 – Install the required software as follows:

For Windows PCs, click here to download and run the following program to install the Anabat Swift USB Driver for Windows. Mac users don’t need to install this driver.

Next, click on one of the following links to download and run the installer for Anabat Insight. Please choose the download that matches your Operating System version.

• Anabat Insight for 64-bit versions of Windows 10, 8, & 7  (most computers)
Anabat Insight for 32-bit versions of Windows (usually older computers with less than 4GB RAM)
Anabat Insight for Mac

Step 2 – Ensure you are connected to the internet. Run Anabat Insight and install any Insight updates that are available. This will be indicated by a green bar near the top of the program window. Ensure the Swift’s battery holder is fitted with fresh batteries.

Step 3 – At the top of the Insight screen, click on the menu that says “Devices”. You should see “Swift” under this menu. Click on “Swift”. (*If you don’t see this then you may have an old firmware version that requires an extra step – in this instance, see below for further instructions).

Step 4 – A window will appear displaying your current firmware version and the latest version available from Titley Scientific. Press the “Download” button to download the new firmware to your computer. Once downloaded, you can press the “Start” button to install the new firmware on your Swift. Once complete, the text “Finished” will appear.

Step 5 – Once the installation is complete, remove the batteries and then reinsert them to restart your Swift with the new firmware. You may get a message about a new “bootloader available”; if so, please proceed with this update by pressing the “Upgrade” button.

*Additional step for old firmware versions
This step may be required before step 3 if you have a particularly old firmware version. Please follow the steps below and then resume the above procedure from step 3.
1. Remove the battery holder from your Swift.
2. Hold down the power button (in the centre above the screen) while re-inserting the batteries. Make sure to hold the button down for a few more seconds after getting the batteries in place. The screen on the Swift will remain black. (This step is required for this firmware update only and will not be needed in the future.)

Troubleshooting

If your Swift fails to turn on after the update, try removing the main battery pack and the clock battery (coin cell) for a few minutes. Reinstall the batteries and then try again.

If you are still encountering any difficulties with this process, please contact Andrew Dobson (andrew.dobson@titley-scientific.com) for assistance.

New Firmware update for the Anabat Scout Bat Detector

Titley Scientific have released a new update for the Anabat Scout Bat Detector. The firmware update (Version 1.0), is an important update that should be applied to all detectors as soon as possible.

The Version 1.0 fixes the following bugs and introduces the following changes:

  • Fixed volume adjustment bug fixed, allowing the detector to remember user-set volumes.
  • Added a trigger min event to settings window.
  • The max memo file time is now set to 10 minutes (was 10 seconds).
  • Added a warning message when clock battery gets low.
  • Disable the audio output when recording a memo; reducing and preventing interference.
  • Fixed a bug that sometimes causes log files to be created in the root directory of the SD card.

Titley Scientific are continually improving the software to add features, remove bugs and address performance issues. It is vital that you install new updates as soon as they become available to ensure your detector runs smoothly.

 

How to perform the update:

Step One – The Anabat Scout is updated by downloading the new software onto an SD card. Simply download the update file using this link (.adx file) and copy this file, in its original format, in the root directory of the SD card. Make sure the file is named scout.adx. You can use the same SD card to update multiple Scouts.

Step Two – Insert the SD card and fresh batteries into your Scout then power it on. After a short period the message: “Firmware update 1.0 available. Would you like to update now?” will appear. Press the “Yes” key (top right hand soft key) to start the update. Do not remove the batteries or power off the detector while the update is being installed. Two squares will scroll across the display while the update is being installed and then the detector will restart. The update is now complete.

Note: To check that the update was successful or that the latest firmware is already installed on the Scout go to: Menu, Other, Update and check the version is 1.0

If any further assistance or advice is required, please get in touch with our equipment team at equipment@nhbs.com.

 

 

 

Kaleidoscope Pro annual subscriptions now available

Kaleidoscope Pro is now available as an annual subscription, providing an economical way to access the excellent analysis features of this software.

A discounted package is also available for students or academics who buy a subscription using an official university purchase order.

Each subscription will give you access to the software for 366 days and an automated email will remind you to renew at the beginning of the month that your current subscription is due to expire.

For customers who have purchased a copy of Kaleidoscope Pro in 2017, Wildlife Acoustics are offering you the chance to convert this to an annual subscription. Depending on when your software was purchased, you will be entitled to a one, two or three-year subscription (see the table below). This offer is valid until the 31st January 2018.

To take advantage of this offer: When Kaleidoscope Pro 4.5 is launched, you will receive a popup window notifying you of the conversion offer. You will be able to accept or decline at this time. If you choose to accept, your permanent license will be deleted.

Echo Meter Touch iOS 11 Firmware Update

Wildlife Acoustics have recently been investigating a problem where first generation (black) Echo Meter Touch units are not working with devices running iOS 11. They have now developed a firmware update which will fix this issue.

Affected models will need to be returned to one of the Wildlife Acoustics service centres: these are located in the US, Australia and the UK. The update will be performed free of charge and your device shipped back to you as quickly as possible.

Only modules with serial numbers greater than EMT00494 are affected. Second generation (red) Echo Meter Touch 2 units are not affected.

Please use the following links to download a return form:
US and Australia repair form
UK repair form

Once units have been updated, any further alterations to the firmware will be able to be performed using a normal app update.

As a gesture of goodwill, Wildlife Acoustics will be donating US$10 for each module that is repaired before 31st January 2018, split between Bat Conservation International and the Bat Conservation Trust.

 

pH Meter Calibration and Maintenance

pH Meters
A pH meter is a key part of the field and lab worker’s tool kit.

Modern pH meters are extremely efficient and provide highly accurate results if they are well looked after and correctly calibrated. A key part of this is taking care of the pH electrode. In this post we will discuss how you can maintain the accuracy and lifespan of your equipment by following correct pH meter calibration, cleaning and storage guidelines.

The main components of the pH meter are the glass electrode and reference electrode which are housed together inside a thin glass membrane. The pH meter calculates pH by measuring the difference in potential, or voltage, between the two. A well cared for electrode will last for up to two years, although use at very high temperatures or with abrasive chemicals may reduce this. It is also important to make sure that you have the correct meter for your sample type: for example, a pH meter designed for use in soil samples will have a different electrode type to one which is designed for liquids.

To maximise the lifespan of your electrode and ensure that it provides consistently accurate readings, a small amount of care and attention is required. Below we answer the most common questions relating to pH meter calibration and care.

How do I calibrate my pH meter?

193227pH meter calibration requires two or more pH buffers. A buffer is a solution of known pH which is used as a standard to ensure the electrode is producing accurate results. The most commonly used buffers are pH 7.0, 4.0 and 10.0. Some pH meters will require two buffers for calibration whilst others require three or more. If you are using only two buffers then you will begin your calibration with the pH 7.0 solution and then use either pH 4.0 or pH 10.0 as your second buffer, depending on whether your sample is acidic or alkaline respectively.

The instructions provided with your meter will detail the calibration process. In general, this will involve dipping your electrode into a buffer and waiting for the reading to stabilise. You will then adjust the pH meter to read the correct pH on the display or, if your meter features automatic calibration, it will automatically adjust itself. This process is repeated with the following buffer(s) until the process is complete and the meter is ready to use. Always remember to rinse your electrode in distilled water between different buffer types and make sure to read your manual carefully before calibrating the meter for the first time.

Buffer solutions are available to purchase in 500ml bottles or as packs of 20ml sachets. Sachets are ideal for infrequent use or for use in the field.

How do I clean my pH electrode?

227513Cleaning your electrode will ensure that it stays in optimum condition and will help to maintain accuracy and efficiency. To use a cleaning solution simply place your electrode in it for 15 to 20 minutes then rinse with distilled water and store as recommended below. For pH meters which are designed for use in soil, a cleaning solution for soil deposits is available which will help to eliminate all impurities and residues which are left on the electrode after use.

How do I store my pH electrode when not in use?

180243When your pH meter is not in use the electrode should be kept immersed in storage solution. This stops the electrode from drying out and keeps it clean and protected until required again. Most pH meters come with either a specially designed cap, into which a small amount of storage solution can be added, or they come with a storage bottle which can be topped up with solution. Make sure to check the level of the storage solution regularly as it will evaporate over time. If the electrode is allowed to dry out then it will no longer function correctly and will have to be replaced.

Take a look at the NHBS website for our full range of pH meters, buffers, cleaning and storage solutions. For replacement electrodes, please contact us to discuss your requirements by phoning +44 (0)1803 865913 or emailing customer.services@nhbs.com

 

Kaleidoscope 4.3.0 Bioacoustic Software Now Available

The newest version of Kaleidoscope, version 4.3.0, is now available to download from the Wildlife Acoustics website.

See below for details about the new features included in this release, as well as a handy table to see which version of Kaleidoscope is right for you, and some useful tutorial videos.

New features include:

New Bat Auto-ID Classifiers
New bat classifiers for North America, Neotropics, Europe and South Africa as well as updated common names for some species. The default setting for classifiers is now “Balanced” which is a useful compromise between the more sensitive and more accurate options.

New time-saving workflow features
New features in the results viewer window include:
• When opening a saved results spreadsheet, a file browser allows you to easily locate the folder containing the corresponding input files
• Bulk ID multiple selected rows
• Bulk copy files in selected rows to a specified folder

Full support for GUANO metadata (Kaleidoscope Pro only)
Kaleidoscope now reads and write GUANO information alongside Wildlife Acoustics metadata (WAMD).  This will been shown in the file at the end of the metadata notes window.

Bug fixes
Several bugs have also been fixed in the new release, details of which can be found in the Kaleidoscope documentation.

Which version of Kaleidoscope is right for me?

Kaleidscope Tutorial Videos


Kaleidoscope UK, Kaleidoscope Neotropics and Kaleidoscope Pro are all available to purchase from NHBS.